Description
Specifications
Operating frequency: | 0.5 MHz |
Magnetic field strength: | 0.28 ± 0.03 Tesla |
Sample diameter: | 10 mm |
Measurement time: | 1-2 minutes |
Resolution: | 0.10% |
Accuracy: | +/- 0.5% |
Measurement range: | 0-100% |
Signal-to-noise ratio: | 60:1 |
Temperature stability: | ± 0.1°C |
Power supply: | 220VAC, 50Hz |
Dimensions: | Magnet box: 445 x 505 x 371 mm; Control cabinet: 560 x 750 x 700 mm |
Weight: | ~200kg |
Operating temperature: | 22-28°C |
Storage temperature: | -10-50°C |
Humidity: | < 30-70% RH |
Computer interface: | USB 2.0 |
Apparatus and Equipment
The Benchtop NMR Analyzer for Seed Oil Content Analysis is a benchtop instrument that utilizes nuclear magnetic resonance (NMR) technology to analyze the oil content of seeds. The instrument features a 0.5 Tesla magnet and a sample diameter of 10 mm. It has a resolution of 0.1% and an accuracy of +/- 0.5%. The measurement time is 1-2 minutes, and the instrument is compact and easy to use.
Protocol
- Turn on the instrument and allow it to warm up for at least 30 minutes.
- Open the sample holder and place a sample of the seed to be analyzed into the sample holder. Make sure the sample is dry and free from any contaminants.
- Close the sample holder and secure it into the instrument.
- Start the measurement by pressing the measurement button on the instrument.
- Wait for the measurement to finish. The instrument will display the results on its LCD screen, which will show the seed oil content as a percentage.
- Record the results as needed. You can also export the results to a computer using the instrument’s USB interface.
- Remove the sample holder from the instrument and clean it thoroughly before using it again.
Literature Reviews
The use of NMR technology for seed oil content analysis has been widely researched and documented. Several studies have shown that NMR analysis provides highly accurate results, and is a faster and more efficient method than traditional techniques such as Soxhlet extraction.
Strengths and Limitations
The Benchtop NMR Analyzer for Seed Oil Content Analysis offers several strengths, including high accuracy and resolution, fast measurement times, and ease of use. However, the instrument’s sample diameter is limited to 10 mm, which may not be suitable for all types of seeds. Additionally, the instrument may require calibration to ensure accurate results.
Summary
The Benchtop NMR Analyzer for Seed Oil Content Analysis provides accurate and efficient analysis of seed oil content. With its advanced technology and easy-to-use design, it is an ideal choice for laboratories, research facilities, and production sites.
References
- T. R. Patil et al., “NMR-Based Seed Oil Content Analysis: A Rapid and Nondestructive Method,” Journal of Agricultural and Food Chemistry, vol. 61, no. 5, pp. 1110-1114, 2013.
- S. A. Ahmed et al., “Seed Oil Content Estimation by Low-Resolution NMR Spectroscopy,” Journal of the American Oil Chemists’ Society, vol. 91, no. 3, pp. 531-536, 2014.
- M. F. Qayyum et al., “Seed Oil Content Analysis by NMR: Comparison with Conventional Methods,” Journal of the American Oil Chemists’ Society, vol. 93, no. 2, pp. 235-243, 2016.